Filter Results By:

Products

Applications

Manufacturers

Showing results: 61 - 75 of 145 items found.

  • Transformer Turns Ratio Meter

    TTRM 302 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.

  • Transformer Turns Ratio Meter

    TTRM 301 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • Contact Resistance Tester

    JYL-200B/100B - Kingrun Instrument Co., Ltd.

    Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups

  • Test Set With Control Unit

    Supreme Instrument Laboratories

    Single Phase A.C. High Voltage Test set (BDV Flash Test) suitable for operation on 230 Volts, A.C. 50 Hz., designed for carrying out dielectric test on transformers, electrical switchgears, and installations. It operates on single phase A.C. and provides an output voltage zero to maximum rated voltage.

  • 300kV/5mA DC Hipot Tester

    HDZG - HD Power Test Equipment Co.ltd

    HDZG-305 300kV/5mA DC high voltage tester is used for testing DC high voltage for zinc oxide arresters,magnetic blowing arresters, power cables,generators,transformers,circuit breakers and other equipments,which is suitable for electric power branch,power department of factories,scientific research units,railway,chemical industry,and power plants.

  • Oil Immersed Test Transformer

    SG-YD - Wuhan Sangao Electrical Test Installations Limit Co.

    AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.

  • Current Booster

    PHPC01 - Ponovo Power Co., Ltd.

    PHPC01 current booster is an accessory which can work together with protection relay test kit to test transformer protection relay testing. It is specifically designed to supply high compliance voltage even at small current range.

  • Highly Inductive Resistance Meter

    MR 8050 - Schuetz Messtechnik GmbH

    With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.

  • Burn Down Transformer

    ATG 6000 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level

  • AC Current Transformers

    CR MAGNETICS, INC.

    CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers. Various outputs include 5 amp secondary, high turns ratio voltage outputs for both wire leads and pcb configurations. Our products are UL Recognized for both US and Canada.

  • Adjustable Isolating Transformers

    PeakTech Prüf- und Messtechnik GmbH

    Is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance.

  • Precision Multirange Current Transformer

    P-2000 - The Eastern Specialty Company

    The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.

  • Tap Adapter

    Techimp HQ S.r.L

    Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.

  • High Voltage Oil Test Set

    Supreme Instrument Laboratories

    Supreme High voltage Oil Testing Apparatus is designed for testing of dielectric strength of transformer Oil or any other insulating liquids. It constitutes a complete equipment and apart of an A.C. supply of 230 / 240 Volts, no other supplementary facilities are required for its operation.

Get Help